Resistance values above the maximum range are possible on special
request.
Resistance values must be checked using 4½ digit micro-ohm meter
with four wire system and insulated clips. The resistance values must be checked at 10mm
from the resistors body.
Electrical and Environmental Characteristics / Data
Test
Performance Requirements
Resistance tolerance
± 10% [K]; ± 5% [J];
± 2% [G]
Rated ambient temperature
at 70°C full power dissipation
Insulation resistance
>1000M[minimum]
Temperature co-efficient
± 200 ppm/°C to ± 1200ppm/°C depending on
resistance value
Short time overload
max D R ± 2%
Moisture Resistance
max D R ± 3%
Load life
max D R ± 5%
Ambient operating temperature range.
-25°C to +155°C
Flame test
UL Specifications have been met satisfactorily.
NOTE:
TAPING :Types C-1AL, C-1L, C-2L, C-3L & C-5L can be supplied in
taped form.