PRODUCT DATA SHEET |
|
LINE MATCHING TRANSFORMER | P3034 |
Features
|
Applications
|
DESCRIPTION
P3034 is the transformer of choice for high-speed applications where low distortion at moderate power levels is required at a competitive price.
P3034 is a drop-in replacement for industry standard P1200 for circuits to be upgraded to V.34 (28,800 bits/second). P3034 is also mechanically and electrically compatible with P2001. Equipment incorporating P3034 will be capable of approval worldwide.
P3034 is certified to EN60950, EN41003 and is supported by a BABT Certificate of Recognition.
SPECIFICATIONS
Electrical
At T = 25�C unless otherwise stated. The convention used in this datasheet is that
'primary' windings are on the line side and 'secondary' windings are on the IC side.
Parameter | Conditions | Min | Typ | Max | Units |
Insertion loss | f = 2kHz, RL = 560 ohms | - | - | 1.5 | dB |
Frequency response | LF-3dB cutoff HF-3dB cutoff 200Hz - 4kHz |
- 10 - |
- - - |
50 - �0.2 |
Hz kHz dB |
Return loss | 200Hz - 4kHz | 18 | - | - | dB |
Third Harmonic Distortion (1) | 450Hz 0dBm in line 300Hz -10dBm 600Hz -10dBm |
- - - |
-78 -92 -105 |
- - - |
dBm dBm dBm |
Balance | DC - 5kHz Method TG25 |
80 | - | - | dB |
Saturation | Excitation 50Hz 250V rms. Output voltage across line |
- - |
- - |
10 65 |
V rms V peak |
Voltage isolation(2) |
50Hz DC |
3.88 5.5 |
- - |
- - |
kV rms kV |
Operating range: Functional Storage Humidity |
Ambient temperature | -10 -40 - |
- - - |
+70 +125 95 |
�C �C %R.H. |
Lumped equivalent circuit parameters as Fig.1
DC resistance, R DC(3) | Sum Of Windings | 118 | 146 | Ohms | |
Leakage inductance L | 14.5 | 18.0 | mH | ||
Shunt inductance Lp(4) | -43dBm 200Hz | 5 | H | ||
Shunt loss Rp(4) | -43dBm 200Hz | 15 | kOhms |
Notes
|
PERFORMANCE CHARACTERISTICS
Figure 5 gives flat RX and TX responses against the reference impedance (typically
around � 0.5dB 300Hz-3.4kHz). Return loss is typically better than 20dB. The circuit
values in parentheses give optimum flatness at a small sacrifice in return loss. For cicuits with existing board drillings, figure 6 gives good return loss (>20dB) and RX flatness against the reference impedance, but TX flatness is degraded by the use of this topology. |
|
SAFETY |
CERTIFICATION |
||||||||||
Manufactured from materials conforming to flammability
requirements of UL94 V-O and EN 60950:1992 (BS7002:1992) sub-clause
1.2,13.2 (V-O). Constructed and vacuum encapsulated in accordance with EN 60950:1992 (BS7002:1992) and EN 41003:1991 (reinforced), excessive voltage 250Vrms. |
Certified by BSI (certificate 7541) to EN 60950:1992 (BS
7002:1992) and IEC 950:1991 sub-clauses 2.2.2, 2.9.1, 2.9.7, 4.4.3 and 5.3 for a maximum
working voltage of 250V, nominal mains supply voltage not exceeding 250V and a maximum
operating temperature of 70�C and EN 41003:1993 sub-clauses 4.2.3(a) and 4.5.3(a). Additionally, ETAL certifies all transformers as providing voltage isolation of 3.88kVrms, 5.5kV DC minimum. All shipments are supported by a certificate of conformity to current BS requirements. Approved and certified by BABT. BABT Certificate of Recognition CR/0136. |
||||||||||
ABSOLUTE MAXIMUM RATINGS |
COPYRIGHT |
||||||||||
Ratings of components independent of circuit).
|
ETAL P1200, P2152 and P3034 are Trade Marks of Electronic Techniques (Anglia) Limited. The Trade Mark ETAL is registered at the UK Trade Marks Registry. Electronic Techniques (Anglia) Limited is the owner of the design right under the Copyright Designs and Patents Act 1988 and no rights or licences are hereby granted or implied to any third party. � 1996 Electronic Techniques (Anglia) Limited. Reproduction prohibited. |
February 1997
ETALDOC 458/3
Home
3506-D, Lake Center Dr., Santa Ana, CA
92704, U.S.A.
714-751-6633
800-527-2888
FAX 714-751-8159
e-mail